Cylindrical Type Inductive M4, M5 ,M6.5, M8(Proximity) Sensors

  • Operating Voltage 10-30 VDC, Brass - Nickel Plated Overload, Short Circuit and Reverse Polarity Protection -25 - + 70 ° C Operating Temperature Protection Class IP67, the load current is 100mA
  Diameter Connection Detection Distance Structure of the Head Supply Output Code



M4 Cable 0.8 mm Straight 10-30 VDC NPN NO IMB0.8-T4-E0
M4 Cable 0.8 mm Straight 10-30 VDC NPN NC IMB0.8-T4-E1
M4 Cable 0.8 mm Straight 10-30 VDC PNP NO IMB0.8-T4-E2
M4 Cable 0.8 mm Straight 10-30 VDC PNP NC IMB0.8-T4-E3
M5 Cable 0.8 mm Straight 10-30 VDC NPN NO IMB0.8-M5E0
M5 Cable 0.8 mm Straight 10-30 VDC NPN NC IMB0.8-M5E1
M5 Cable 0.8 mm Straight 10-30 VDC PNP NO IMB0.8-M5E2
M5 Cable 0.8 mm Straight 10-30 VDC PNP PC IMB0.8-M5E3
M6.5 Cable 1.5 mm Straight 10-30 VDC NPN NO IMB1.5-T6.5-E0
M6.5 Cable 1.5 mm Straight 10-30 VDC NPN PC IMB1.5-T6.5-E1
M6.5 Cable 1.5 mm Straight 10-30 VDC PNP NO IMB1.5-T6.5-E2
M6.5 Cable 1.5 mm Straight 10-30 VDC PNP PC IMB1.5-T6.5-E3

Extended Detection M8(Proximity) Sensors

  • Operating Voltage 10-30 VDC, Brass - Nickel Plated Overload, Short Circuit and Reverse Polarity Protection -25 - + 70 ° C Operating Temperature Protection Class IP67, the load current is 100mA
  Diameter Connection Detection Distance Structure of the Head Supply Output Code

M8 Cable 2 mm Straight 10-30 VDC NPN NO IMB2-M8-E0
M8 Cable 2 mm Straight 10-30 VDC NPN NC IMB2-M8-E1
M8 Cable 2 mm Straight 10-30 VDC PNP NO IMB2-M8-E2
M8 Cable 2 mm Straight 10-30 VDC PNP NC IMB2-M8-E3
M8 Cable 2 mm Straight 10-30 VDC NPN NO IMB2-M8-E0
M8 Cable 2 mm Straight 10-30 VDC PNP NO IMB2-M8-E2
M8 Cable 2 mm Straight 10-30 VDC NPN NO IMB2-M8-E0C
M8 Cable 2 mm Straight 10-30 VDC PNP NO IMB2-M8-E2C
M8 Cable 3 mm Dislocation 10-30 VDC NPN NO IMN3-M8-E0
M8 Cable 3 mm Dislocation 10-30 VDC NPN NC IMN3-M8-E1
M8 Cable 3 mm Dislocation 10-30 VDC PNP NO IMN3-M8-E2
M8 Cable 3 mm Dislocation 10-30 VDC PNP NC IMN3-M8-E3
M8 M8 ConNT. 3 mm Dislocation 10-30 VDC NPN NO IMN3-M8-E0C8
M8 M8 ConNT. 3 mm Dislocation 10-30 VDC PNP NO IMN3-M8-E2C8
M8 M12 ConNT. 3 mm Dislocation 10-30 VDC NPN NO IMN3-M8-E0C
M8 M12 ConNT. 3 mm Dislocation 10-30 VDC PNP NO IMN3-M8-E2C

Extended Detection M12(Proximity) Sensors

  • Operating Voltage 10-30 VDC and 90-250VAC. Brass - Nickel Plated Overload, Short Circuit and Reverse Polarity Protection -25 - + 70 ° C Operating Temperature Protection Class IP67, the load current is 100mA
  Diameter Connection Detection Distance Structure of the Head Supply Output Code




M12 Cable 4 mm Straight 10-30 VDC NPN NO IMB4-M12-E0
M12 Cable 4 mm Straight 10-30 VDC NPN NC IMB4-M12-E1
M12 Cable 4 mm Straight 10-30 VDC PNP NO IMB4-M12-E2
M12 Cable 4 mm Straight 10-30 VDC PNP NC IMB4-M12-E3
M12 M12 Con. 4 mm Straight 10-30 VDC NPN NO IMB4-M12-E0C
M12 M12 Con. 4 mm Straight 10-30 VDC NPN NC IMB4-M12-E1C
M12 M12 Con. 4 mm Straight 10-30 VDC PNP NO IMB4-M12-E2C
M12 M12 Con. 4 mm Straight 10-30 VDC PNP NC IMB4-M12-E3C
M12 Cable 6 mm Dislocation 10-30 VDC NPN NO IMN6-M12-E0
M12 Cable 6 mm Dislocation 10-30 VDC NPN NC IMN6-M12-E1
M12 Cable 6 mm Dislocation 10-30 VDC PNP NO IMN6-M12-E2
M12 Cable 6 mm Dislocation 10-30 VDC PNP NC IMN6-M12-E3
M12 M12 Con. 6 mm Dislocation 10-30 VDC NPN NO IMN6-M12-E0C
M12 M12 Con. 6 mm Dislocation 10-30 VDC NPN NC IMN6-M12-E1C
M12 M12 Con. 6 mm Dislocation 10-30 VDC PNP NO IMN6-M12-E2C
M12 M12 Con. 6 mm Dislocation 10-30 VDC PNP NC IMN6-M12-E3C
M12 Cable 4 mm Straight 10-30 VDC NPN NO+NC IMB4-M12-A0
M12 Cable 4 mm Straight 10-30 VDC PNP NO+NC IMB4-M12-A2
M12 Cable 6 mm Dislocation 10-30 VDC NPN NO+NC IMN6-M12-A0
M12 Cable 6 mm Dislocation 10-30 VDC PNP NO+NC IMN6-M12-A2
M12 Cable 4 mm Straight 90-250 VAC NO IMB4-M12-WO
M12 Cable 4 mm Straight 90-250 VAC NC IMB4-M12-WS
M12 Cable 6 mm Dislocation 90-250 VAC NO IMN6-M12-WO
M12 Cable 6 mm Dislocation 90-250 VAC NC IMN6-M12-WS

Extended Detection M18(Proximity) Sensors

  • Operating Voltage 10-30 VDC and 90-250VAC. Brass - Nickel Plated Overload, Short Circuit and Reverse Polarity Protection -25 - + 70 ° C Operating Temperature Protection Class IP67, the load current is 100mA
  Diameter Connection Detection Distance Structure of the Head Supply Output Code




M18 Cable 8 mm Straight 10-30 VDC NPN NO IMB8-M18-E0
M18 Cable 8 mm Straight 10-30 VDC NPN NC IMB8-M18-E1
M18 Cable 8 mm Straight 10-30 VDC PNP NO IMB8-M18-E2
M18 Cable 8 mm Straight 10-30 VDC PNP NC IMB8-M18-E3
M18 M12 Con. 8 mm Straight 10-30 VDC NPN NO IMB8-M18-E0C
M18 M12 Con. 8 mm Straight 10-30 VDC NPN NC IMB8-M18-E1C
M18 M12 Con. 8 mm Straight 10-30 VDC PNP NO IMB8-M18-E2C
M18 M12 Con. 8 mm Straight 10-30 VDC PNP NC IMB8-M18-E3C
M18 Cable 12 mm Dislocation 10-30 VDC NPN NO IMN12-M18-E0
M18 Cable 12 mm Dislocation 10-30 VDC NPN NC IMN12-M18-E1
M18 Cable 12 mm Dislocation 10-30 VDC PNP NO IMN12-M18-E2
M18 Cable 12 mm Dislocation 10-30 VDC PNP NC IMN12-M18-E3
M18 M12 Con. 12 mm Dislocation 10-30 VDC NPN NO IMN12-M18-E0C
M18 M12 Con. 12 mm Dislocation 10-30 VDC NPN NC IMN12-M18-E1C
M18 M12 Con. 12 mm Dislocation 10-30 VDC PNP NO IMN12-M18-E2C
M18 M12 Con. 12 mm Dislocation 10-30 VDC PNP NC IMN12-M18-E3C
M18 Cable 8 mm Straight 10-30 VDC NPN NO+NC IMB8-M18-A0
M18 Cable 8 mm Straight 10-30 VDC PNP NO+NC IMB8-M18-A2
M18 Cable 12 mm Dislocation 10-30 VDC NPN NO+NC IMN12-M18-A0
M18 Cable 12 mm Dislocation 10-30 VDC PNP NO+NC IMN12-M18-A2
M18 Cable 8 mm Straight 90-250 VDC NO IMB8-M18-WO
M18 Cable 8 mm Straight 90-250 VDC NC IMB8-M18-WS
M18 Cable 12 mm Dislocation 90-250 VAC NO IMN12-M18-WO
M18 Cable 12 mm Dislocation 90-250 VAC NC IMN12-M18-WS

Extended Detection M30(Proximity) Sensors

  • Operating Voltage 10-30 VDC and 90-250VAC. Brass - Nickel Plated Overload, Short Circuit and Reverse Polarity Protection -25 - + 70 ° C Operating Temperature Protection Class IP67, the load current is 100mA
  Diameter Connection Detection Distance Structure of the Head Supply Output Code
M30 M12 Con 10 mm Straight 10-30 VDC NPN NO IMB10-M30-E0C
M30 M12 Con 10 mm Straight 10-30 VDC NPN NC IMB10-M30-E1C
M30 M12 Con 10 mm Straight 10-30 VDC PNP NO IMB10-M30-E2C
M30 M12 Con 10 mm Straight 10-30 VDC PNP NC IMB10-M30-E3C
M30 M12 Con. 15 mm Dislocation 10-30 VDC NPN NO IMN15-M30-E0C
M30 M12 Con. 15 mm Dislocation 10-30 VDC NPN NC IMN15-M30-E1C
M30 M12 Con. 15 mm Dislocation 10-30 VDC PNP NO IMN15-M30-E2C
M30 M12 Con. 15 mm Dislocation 10-30 VDC PNP NC IMN15-M30-E3C
M30 Cable 10 mm Straight 10-30 VDC NPN NO+NC IMB10-M30-A0
M30 Cable 10 mm Straight 10-30 VDC PNP NO+NC IMB10-M30-A2
M30 Cable 15 mm Dislocation 10-30 VDC NPN NO+NC IMN15-M30-A0
M30 Cable 15 mm Dislocation 10-30 VDC PNP NO+NC IMN15-M30-A2
M30 Cable 5 mm Straight 10-30 VDC NPN NO+NC IMB15-M30-A0
M30 Cable 1.5 mm Straight 10-30 VDC PNP NO+NC IMB15-M30-A2
M30 Cable 10 mm Straight 90-250 VAC NO IMB10-M30-WO
M30 Cable 10 mm Straight 90-250 VAC NC IMB10-M30-WS
M30 Cable 15 mm Dislocation 90-250 VAC NO IMN15-M30-WO
M30 Cable 15 mm Dislocation 90-250 VAC NC IMN15-M30-WS

Piston Tip Manyetik Sensörler

  • Pirinç - Nikel Kaplamalı Aşırı Yük, Kısa Devre ve Ters Polarite Korumalı -25- +70 C Çalışma Sıcaklığı IP67 Koruma Sınıfı, Yük Akımı 100mA
  Connection Dimensions Supply Output Code
2 Wires 25.5x4mm 5-120 VDC-AC NO IS-06R-2M
2 Wires 30x6.3mm 5-120 VDC-AC NO IS-50R-2M
2 Wires 25.5x4mm 5-120 VDC-AC NO IS-072R-3M